The Kneeboard
Community is here!
Create a profile:
tell your Knee Story!
Check out the new
Knee article library!
Bob's ACL WWWBoard (http://factotem.org) -- On-Line Knee Library

Bob's ACL WWWBoard

On-Line Knee Library

Compiled by Michael Frind. Site last updated Wednesday, January 30, 2008.

Click here to return to the subsection ACL Reconstructions via Hamstring Autografts.


------


Document Title: Magen-AJSM-Jan99

Article Title: Structural properties of six tibial fixation methods for anterior cruciate ligament soft-tissue grafts

Authors: Hugh E. Magen, Stephen M. Howell, Maury L. Hull.

Publication: The American Journal of Sports Medicine

ISSN: 03635465

Date: January-February 1999.

(Figures included. Reference-denoting numbers appear in the same point size as document text.)

Volume: 27

Issue: 1

Pages: 35-43

Key Words: Knee, ACL, ligaments, surgery, fixation, graft, sports medicine

 

This article discusses soft-tissue-type graft anchorage, as pertaining to hamstring-type (DLSTG) ACL grafts.

 

ABSTRACT

 

This study compared the stiffness (K), yield load (YL), and slippage (SL) of six tibial fixation methods. These properties were determined from load-to-failure and cyclic tests of double-looped tendon grafts fixed to both animal and young human tissue. Tandem washers (K = 259 N/mm, YL = 1159 N, SL = 0.5 mm) and the Washerloc (K = 248 N/mm, YL = 905 N, SL = 2.0 mm) were the two best fixations. At 500 N of load, which is the estimated daily tension of an anterior cruciate ligament graft during intensive rehabilitation, slippage was significantly greater in either of the other two methods for sutures tied to a post (4.9 mm), double staples (3.3 mm), and a 20-mm spiked metal washer (3.5 mm). Interference screw fixation performed well in animal tissue (YL = 776 N), but was significantly worse in young human tissue (YL = 350 N), with 57% of the fixations failing before 500 N of load. Animal tissue should not be used to estimate the performance of interference screw fixation in human tissue. Because 57% of the interference screw fixations using human tissue failed at loads below 500 N, their ability to provide adequate fixation during intensive rehabilitation should be questioned. However, both the Washerloc and tandem washers and screws provide fixation structural properties in young human tibia that should be appropriate for intensive rehabilitation.

 


To access the full text of this article, please click here.
There is no charge for viewing articles. However, a password is required.
If you do not already have a password, please e-mail Michael Frind at frind@execulink.com for one.
Prior to requesting a password, please make certain you have read the Site Terms of Use pertaining to this site.


- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Copyright American Journal of Sports Medicine Jan/Feb 1999.  For details regarding copyright as it applies to this page, please visit the page entitled "Site Terms of Use and Aspects of Copyright" on this site.

This website was created for the benefit of the world's largest knee-injury community, Bob's ACL WWWBoard, accessible to everyone at http://factotem.org.

Documents posted on this site serve merely as a virtual library, and are intended solely for purposes of making access to high-quality peer-reviewed medical journals convenient for everyone.  Knee-injury patients are hereby encouraged to discuss this material with their respective medical teams.


Click here to return to the Main Entrance Page of the Knee Library.

Looking for the Main Index Page of Bob's ACL WWWBoard? Click here!

To find recent postings on Bob's ACL WWWBoard, use the Search Engine.

To find older postings on Bob's ACL WWWBoard, use the On-Line Archive.


Site Terms of Use and Aspects of Copyright

Printing Hints and Tips